Tips & Advice
Explaining Heat Pump Auxiliary Heat: Why It Activates During Chilly November Nights

The Sudden Appearance of the 'Aux Heat' Indicator
Late fall in our region brings a specific kind of weather, and explaining heat pump auxiliary heat is the best way to help you understand why your thermostat suddenly displays a new alert before the first winter freeze even arrives. Here at Eagle Pipe Heating & Air, our team has spent years helping Poulsbo homeowners navigate those chilly, damp November nights in the Pacific Northwest. You wake up, walk past your thermostat, and notice the "Aux Heat" indicator glowing brightly. For many homeowners, this immediately triggers a sinking feeling. You might wonder if your primary heating system has failed, if you are suddenly burning through massive amounts of electricity, or if you need to schedule an emergency repair before the weather gets worse.
The short answer is that seeing this alert during a late fall cold snap is usually a built-in protective feature rather than an immediate emergency. Your system is designed to adapt to dropping temperatures, and understanding how it makes those adjustments can save you a lot of unnecessary worry.
Need help with your system? Explore our heat pump and air conditioning systems, or schedule heat pump repair service in Poulsbo if you suspect a deeper issue.
What Exactly Is Auxiliary Heat and How Does It Work?
To understand why your thermostat is giving you this notification, it helps to know exactly what auxiliary heat is and how it functions inside your HVAC system. A standard heat pump does not actually generate heat the way a gas furnace does. Instead, it extracts ambient heat energy from the outside air and moves it inside your home. Even when it feels freezing outside, there is still heat energy in the air. However, as the temperature plummets, it becomes harder and harder for the outdoor unit to extract that heat efficiently.
Auxiliary heat refers to a set of electric resistance heating strips located inside your indoor air handler. Think of them like the glowing orange coils inside a toaster or a space heater, just on a much larger scale. When the heat pump can no longer pull enough warmth from the outdoor air to keep your house at the temperature you set, it activates these electric strips to supplement the heating process.
This creates a crucial distinction between primary heat pump operation (which relies on transferring refrigerant) and auxiliary heating (which relies on direct electrical resistance). The primary method is incredibly energy-efficient, while the auxiliary method uses more electricity to bridge the gap.
The Mechanics of Supplemental Heating
Your thermostat acts as the brain of this entire operation. It constantly monitors both the indoor temperature and the output of the heat pump. If you set your thermostat to 70 degrees, but the indoor temperature drops to 68 degrees and the heat pump is already running at full capacity, the thermostat recognizes that the system needs help. It sends a signal to the indoor air handler to engage the electric strips.
This process is entirely automated to ensure consistent indoor comfort. You do not have to manually flip a switch to turn on the auxiliary heat. The system calculates its own "balance point"—the exact moment where the heat pump's output matches the heat loss of your home—and seamlessly activates the strips to prevent your house from getting cold.
The 35-40 Degree Threshold: Decoding the Temperature Trigger
One of the most common questions our Eagle Pipe Heating & Air technicians hear from local homeowners is exactly when this supplemental heating is supposed to kick in. Based on the systems we service throughout Poulsbo, the magic number revolves around the 35-40 degree outdoor temperatures that often trigger heat pump defrost mode. When the weather outside drops into this specific range, standard heat pumps begin to lose their primary efficiency.
It is important to understand that your heat pump does not shut down when it hits 39 degrees. It continues to extract as much heat as it possibly can from the outdoor air. The auxiliary heat simply turns on to supplement the output. If the heat pump can only provide 80% of the warmth needed to maintain your set temperature, the electric strips provide the remaining 20%.
Reassure yourself that noticing the indicator in this specific temperature range is mechanically expected. It is a sign that your system is working exactly as the manufacturer intended.
| Outdoor Temperature Range | System Operation Mode | Homeowner Action Required |
|---|---|---|
| Above 40°F | Primary heat pump operation (highly efficient). | None. System maintains comfort easily. |
| 35°F to 40°F | Heat pump runs, occasional auxiliary heat supplements. | None. Normal operation for chilly weather. |
| Below 30°F | Heavy reliance on auxiliary heat strips. | Monitor energy use; normal for freezing snaps. |
Defrost Mode: Your Heat Pump's Built-In Defense Mechanism
The Problem: When outdoor temperatures hover just above freezing, the outdoor coil of your heat pump gets very cold as it extracts heat. Because there is moisture in the air, condensation forms on the metal fins of the coil. When the coil temperature drops below freezing, that condensation turns into a layer of frost or solid ice. If this ice builds up too much, it blocks airflow, making it impossible for the system to absorb heat.
The Cause: This frosting is a natural consequence of refrigeration physics. The system has to remain colder than the outdoor air in order to absorb heat from it. During those 35-40 degree outdoor temperatures that often trigger heat pump defrost mode, the conditions are perfectly primed for rapid ice accumulation.
The Solution: To protect itself from turning into a solid block of ice, your heat pump has a built-in defrost cycle. The system temporarily reverses its operation. It switches back into air conditioning mode for a few minutes, sending hot refrigerant out to the outdoor unit to melt the ice. However, because it is running in AC mode, it is technically pushing cold air toward your indoor vents. To prevent freezing cold air from blowing into your living room on a chilly November night, the system automatically activates the auxiliary heat strips to warm that air before it reaches you.
This is why you frequently see the "Aux Heat" light turn on during a defrost cycle. It is a temporary, protective feature designed to keep the outdoor unit clear of ice while maintaining your indoor comfort.

Why Pacific Northwest Humidity Accelerates Coil Frosting
If you talk to someone living in a dry, high-altitude climate, they might rarely see their auxiliary heat turn on until the temperature drops to zero. So why does it happen so often here? The team at Eagle Pipe Heating & Air knows firsthand that the answer lies in the unique environment of our region. Chilly, damp November nights in the Pacific Northwest create the perfect storm for heat pump frosting.
In a dry, freezing climate, there is very little moisture in the air to freeze onto the coils. In contrast, our local late-fall weather is characterized by incredibly high relative humidity. The air is heavy with moisture. When that damp air gets pulled across a cold heat pump coil, it deposits a massive amount of condensation, which rapidly freezes.
Because frost builds up much faster in high-humidity environments, your system is forced to enter defrost mode more frequently to protect itself. Every time it enters defrost mode, it activates the auxiliary heat. This means that seeing the alert on your thermostat is largely a product of our specific geographic location. Understanding why your heat pump struggles with humidity spikes helps explain why this frequency is completely normal for homes in our area.
Normal Defrost Cycles vs. Warning Signs of a Malfunction
While occasional auxiliary heating is normal, you still need to know how to spot a system that is actually struggling. Distinguishing between a routine defrost cycle and a mechanical failure can save you from an unnecessary panic call, while also ensuring you don't ignore a real problem.
Here is a checklist of what a normal defrost cycle looks like on those chilly, damp November nights in the Pacific Northwest:
- Short duration: The "Aux Heat" light only stays on for 5 to 15 minutes at a time.
- Weather alignment: It only happens when it is cold and damp outside (typically under 40 degrees).
- Outdoor steam: You may see a cloud of steam rising from the outdoor unit as the ice melts (this is normal vapor, not smoke).
- Consistent comfort: Your home stays at the temperature you set on the thermostat.
When to Call a Professional
If your system is exhibiting warning signs, it is time to have a technician take a look. Never attempt DIY electrical or refrigerant troubleshooting, as these systems carry high voltage and require specialized licensing to handle safely. Watch out for these red flags:
- Mild weather activation: Auxiliary heat stays on when outdoor temperatures are mild (above 45 degrees).
- Constant running: The auxiliary heat runs for hours at a time without shutting off.
- Ice blocks: The outdoor unit is encased in solid ice that doesn't melt away after a defrost cycle.
- Unusual noises: Grinding, screeching, or buzzing sounds accompany the auxiliary heat activation.
Routine professional upkeep is the best way to prevent the system from getting stuck in auxiliary mode. Scheduling seasonal heat pump maintenance ensures that all sensors, relays, and refrigerant levels are calibrated perfectly before the harsh winter weather arrives.
Pre-Winter Readiness: When to Consider a System Upgrade
As you prepare your home for the colder months, it is worth evaluating how heavily your current system relies on its electric strips. A pattern our technicians see often during late fall maintenance calls is that older heat pumps lose their efficiency at higher temperatures than modern units. A heat pump installed fifteen years ago might start struggling and switching to auxiliary power when it is 42 degrees outside, whereas a newer model might run efficiently down to 25 degrees or lower.
Frequent, prolonged use of auxiliary heat can significantly impact your energy efficiency over the winter. Because electric resistance strips consume far more electricity than the heat pump compressor, an older system that gets stuck relying on supplemental power will cause a noticeable spike in your monthly utility usage.
Modern systems have much lower balance points, heavily reducing the need for electric strip heating even during those 35-40 degree outdoor temperatures that often trigger heat pump defrost mode in older units. If your current unit is aging and constantly leaning on the backup strips to keep you warm, it might be time to look into heat pump replacement. Keep in mind that general energy rebates or federal tax credits may apply to qualifying modern installations, so we always advise verifying current programs with your utility provider or a tax professional to see how much you could save on an upgrade.
Frequently Asked Questions About Auxiliary Heating
Is it normal for aux heat to come on?
Yes, it is completely normal for auxiliary heat to activate during cold weather. It is a built-in feature designed to help your system maintain indoor comfort when the outdoor temperature drops too low for the heat pump to work efficiently on its own. You will most commonly see it turn on during the system's automatic defrost cycle.
At what temperature does aux heat come on?
For most standard heat pumps, auxiliary heat typically begins to activate when outdoor temperatures drop into the 35-40 degree range. At this threshold, the system starts losing its primary heat transfer efficiency and requires supplemental electric heat to bridge the gap. Modern, high-efficiency models may have a lower threshold.
Why is my heat pump blowing cold air then aux heat comes on?
This happens because your heat pump has entered defrost mode to melt ice off the outdoor coils. To do this, it temporarily reverses into air conditioning mode, which pushes cold air toward your vents. The system automatically turns on the auxiliary heat strips to warm up that cold air before it blows into your living space.
How do I turn off auxiliary heat on my thermostat?
You generally should not try to disable auxiliary heat, as your system relies on it to protect the compressor and maintain indoor temperatures during freezing weather. If you want to minimize its use, lower your thermostat set point by a few degrees so the primary heat pump doesn't have to work as hard to reach the target temperature.
Does auxiliary heat consume more electricity than normal heating?
Yes, auxiliary heat uses significantly more electricity than standard heat pump operation. The primary heat pump transfers existing heat from the outdoors, which is highly efficient. Auxiliary heat uses electric resistance strips to generate new heat, which requires a much larger draw of electrical power.
Can high humidity cause auxiliary heat to activate more often?
Absolutely. High humidity levels in the air cause moisture to freeze onto the outdoor coils much faster when temperatures drop near freezing. Because the coils ice up more rapidly, the system has to run its defrost cycle more frequently, which in turn triggers the auxiliary heat more often to keep your indoor air warm.
Staying Comfortable and Confident This Winter
Waking up to a new notification on your thermostat doesn't have to be a stressful event. By understanding the mechanics behind your system, you can rest easy knowing that auxiliary heat is a protective feature, not an automatic cause for alarm. Those chilly, damp November nights in the Pacific Northwest demand a lot from your heating equipment, and your system is simply adapting to keep your family comfortable.
Understanding this process brings peace of mind as we move deeper into late fall and winter. If you notice any of the warning signs we discussed, or if you just want to ensure your system is fully prepared for the upcoming freezes, don't hesitate to reach out for a professional system check. We are always here to help with explaining heat pump auxiliary heat and keeping your home perfectly warm all season long.
Keep reading
Related articles.
Ready when you are
Need a tech who answers back?
Same-week scheduling across Kitsap and Jefferson County. Honest quotes, no pressure.